Electronic Communications Act, 2005 (Act No. 36 of 2005)RegulationsRegulations on the use of Television White Spaces, 20188. Location Specific Maximum Permitted Radiated Power Levels |
(1) | The maximum allowed to transmit EIRP of WSD must not exceed the values shown in Table 1. |
(2) | The secondary GLSD may instruct the Master WSD to adjust to lower EIRPs than those shown in Table 1 in order not to exceed the incumbent's protection thresholds. |
(3) | An additional 7dB of power must be added to the maximum EIRP level per 8 MHz channel for WSDs operating indoors to compensate for in-building penetration losses. |
Table 1 Maximum permitted location specific WSD EIRP and EIRP spectral density
Location |
Type of WSD |
EIRP per 8 MHz channel (dBm) |
EIRP per 100 kHz channel (dBm) |
Rural |
Fixed |
41.2 |
22.2 |
Urban |
Fixed |
36 |
17 |
Rural |
Nomadic |
20 |
1 |
Urban |
Nomadic |
20 |
1 |