Marine Pollution (Prevention of Pollution from Ships) Act, 1986 (Act No. 2 of 1986)

Schedule

International Convention for the Prevention of Pollution from Ships, 1973

Protocol of 1978

Relating to the International Convention for the Prevention of Pollution from Ships, 1973

Annexes : Regulations

Annex I : Regulations for the Prevention of Pollution by Oil

Chapter II : Requirements for Control of Operational Pollution

Regulation 19 : Standard Discharge Connection

Purchase cart Previous page Return to chapter overview Next page

 

To enable pipes of reception facilities to be connected with the ship's discharge pipeline for residues from machinery bilges, both lines shall be fitted with a standard discharge connection in accordance with the following table:

 

STANDARD DIMENSIONS OF FLANGES FOR DISCHARGE CONNECTIONS

 

Description

Dimension

Outside diameter

215mm.

Inside diamter

According to pipe outside diameter.


183 mm.


6 holes 22 mm in diameter equidistantly placed on a bolt circle of the above diameter, slotted to the flange periphery. The slot width to be 22 mm.

Flange thickness

20 mm.

Bolts and nuts: quantity diameter

6, each of 20 mm in diameter and suitable length.

The flange is designed to accept pipes up to a maximum internal diameter of 125 mm and shall be of steel or other equivalent material having a flat face. This flange, together with a gasket of oilproof material, shall be suitable for a service pressure of 6 kg/cm2.