This procedure shall be carried out if the unit’s breathing bag does not inflate immediately after activating the starter.

 

In this case:

 

1. Remove nose clip.
2. Inhale from ambient atmosphere through nose.
3. Exhale into mouth piece.
4. Repeat above actions six times with a full breath each time.
5. Refit nose clip.
6. Breathe normally into the mouthpiece.

 

This procedure shall be included into the training procedures, where applicable.