Hazard
|
Dangers associated with the hazard
|
Hanging wall / roof / sidewall / rib side.
|
• | Working places that have not first been examined and made safe as required by regulation 14.1 (FOG regulations). |
• | Working places where safety pillars have been removed or do not adhere to the minimum safety pillar dimensions. |
• | Missing or blasted out support. |
|
Winches and rigging.
|
• | Winch not anchored or incorrectly anchored. |
• | Open electrical connections. |
• | Snatch blocks not anchored correctly. |
• | No signalling arrangements. |
|
Ventilation and temperatures.
|
• | Dust levels in the atmosphere exceed the specified maximum. |
• | Airflow has been restricted. |
• | Temperatures exceed the maximum allowable or have increased considerably. |
|
Gas accumulations and fumes
|
• | The presence of flammable and/or noxious gasses which exceed the maximum permissible limits. |
|
Water accumulations, flow of water.
|
• | Any abnormal water flows from strata or drilled holes. |
• | Any major water flows from ore passes and box holes. |
• | Any accumulation of water of unknown depth. |
|
Flow of broken rock, mud or slimes
|
• | Uncontrolled flow of rock, mud from ore passes or box holes. |
• | Any imminent or initiated flow of mud from the top or side of mine tailings facilities. |
|
Misfires, explosives.
|
• | Any misfired hole with which the crew cannot deal. |
• | Any accumulation of explosives, especially old explosives. |
|
Fires and explosions.
|
• | Any fire or explosion in other parts of the mine which could affect the working place. |
• | Any working place which constitutes a "hazardous location" (as defined in MHSA regulations chapter 10 dealing with hazardous locations) and in which apparatus is used that is not "explosion protected apparatus", as defined in the regulations. |
|
Defective equipment and vehicles.
|
• | Equipment and vehicles which prove to have defects during pre‐service examination. |
• | Equipment and vehicles which become defective or inoperative during the shift. |
|
Power failure.
|
• | Power failure, local or general, which may affect the operation of fans and other critical equipment. |
|
Dangerous electrical equipment and installations.
|
• | Open connections, frayed cables, etc. |
|
Lack of illumination.
|
• | No or ineffective illumination at equipment and machinery, where moving parts can endanger safety. |
|
Inadequate personal protective equipment (PPE).
|
• | Non‐availability of PPE. |
• | Damaged or worn PPE not replaced. |
• | Inappropriate selection/below standard PPE. |
|
Inadequate training
|
• | Inadequate training to perform a task safely (including basic, induction, refresher training). |
• | Inadequate training on the major hazards (including basic, induction, refresher training). |
|
Unacceptable and dangerous behaviour of colleagues.
|
• | Including substance abuse at work. |
• Aggressive or violent behaviour.
• Inadequate training, experience or licencing for the job.
|
Noise
|
• | Noise levels not to exceed the specified maximum. |
• | Engineering interventions to be introduced to restrict levels at source. |
• | Noise levels that cannot be limited to have correct identified PPE provided. |
|