106. Pressure testing of the blowout prevention equipment

Purchase cart Previous page Return to chapter overview Next page

 

(1)The blowout prevention equipment must be tested to 100% of rated working pressure and the annular-type blowout preventer must be tested to 1,000 psi (6894.76 kPa) at the time of installation in accordance with current API std 53 for blowout equipment.

 

(2)

(a)Testing of blowout prevention equipment for a drilling or completion operation must take place prior to drilling below the last cemented casing seat.
(b)The holder must maintain a record of the pressure tests and submit the record to the designated agency.

 

(3)A holder must notify the designated agency at least 2 days prior to conducting a blowout preventer test to enable an authorised person to be present when the test is done.

 

(4)Blowout prevention equipment that has failed any pressure test must not be used until it is repaired and passes the pressure test.

 

[Regulation106 inserted by section 2 of Notice No. R. 466 dated 3 June 2015]